← Project library
WaterWater Sentinel Sewer saline intrusion tracing & H2S scrubber dosing

Which branch is carrying salt into your sewer?

A pumping-station alarm tells you salt has arrived. Pipe maps and portable loggers can help crews decide which upstream reach to investigate next.

Water Sentinel — Sewer saline intrusion tracing & H2S scrubber dosing

For a wastewater network operator. In Dubai, the sewer network is run by Dubai Municipality, with which Nodal has no agreement.

Today in the UAE

AED 80 billion

Dubai is investing AED 80 billion in the Dubai Strategic Sewerage Tunnels: 75 km of deep tunnels and 242 km of link sewers, which will replace more than 100 pumping stations and are expected to save 450 GWh a year (Dubai Municipality, 1 Oct 2025).

Proof to date

Simulated, internal review

About 7 nights

In 32 simulated campaigns not used for tuning, hidden salt-water inflows were pinned in about 7 nights on average, against 11 to 15 for an expert using the same 20 loggers and 19 to 22 for a fixed station meter. Scrubber caustic fell 12 to 13% against a time-banded pH schedule, with 98% of hours within the limit against 94 to 97%. A tuned operator rule on the same sensor used 1 to 2% less caustic, with more hours over the limit.

How to start

4-week catchment diagnostic · AED 0 upfront

Records your control room already keeps, exported read-only: conductivity and H2S logs, the sewer map, dewatering permits and known salty discharges for one catchment. No hardware and no control-system login in the first four weeks. A shadow pilot follows on terms agreed after the study.

Limits

  • A synthetic catchment with one pumping station, not Dubai's network. Almost every parameter is assumed, and there is no cost figure and no forecast.
  • The gain is mostly time. Within 14 nights the expert had also pinned at least two of three inflows in 51 of 64 campaigns, against 59 of 64 within 5 nights for the system (the 32 campaigns above and 32 fresh ones run by the reviewer).
  • With 8 loggers instead of 20 the system made about 4.6 more wasted inspections per campaign than the expert, and with 4 loggers about 2.8 more.
  • The lead over the expert is not statistically clear if a wasted inspection costs three nights, if the water table sits deeper, or if rags snag the loggers three times as often.
  • The 7-night average counts an inflow that was never found as the rest of the six-week campaign.
  • Staying within the limit needs accurate H2S sensors, and the caustic saving needs a scrubber near its published curve. At twice the simulated sulphide load the saving fell to 4.5%, with 10% of hours over the limit.
In Dubai, the sewer network is run by Dubai Municipality (no agreement with Nodal)

Inside the operating model.

Pilot design

What the first test must prove.

Start at AED 0

2-page executive brief (PDF) ↓1-page read-only CSV checklist (PDF) ↓

Water Sentinel field verification
Illustrative image
The decision
Where should the field team place its next logger to narrow the source before another night passes?
How we would test it
Trace readings through one catchment and rank the next sampling points. If odour dosing is also studied, plant operators set the outlet limits and authorise adjustments.
Evidence & target
Stage: Simulated, internal review (synthetic single-station catchment; 64 distinct campaigns: 16 author + 16 held-back + 32 stress seeds). In 32 unseen campaigns, hidden salt inflows were pinned in ~7 nights on average vs 11–15 for an expert moving the same 20 loggers and 19–22 for a fixed station meter (59/64 pinned ≥2 of 3 inflows within 5 nights vs 51/64 within 14 nights for the expert). Limits: with 8 or 4 loggers it made ~4.6 or ~2.8 more wasted checks than the expert; lead over the expert is not statistically clear with a deeper water table, 3-night wasted-check cost or 3× ragging. Scrubber caustic fell 12–13% vs a pH schedule (98% vs 94–97% hours in limit; at 2× sulphide load Nodal's saving fell to 4.5% with 10% hours over limit), while a tuned operator rule used 1–2% less caustic with more hours over limit.
A first step (AED 0 upfront)
4-week catchment diagnostic at AED 0 upfront on read-only conductivity and H2S logs, sewer maps, dewatering permits and known saline discharges for one catchment (zero hardware and zero SCADA login in weeks 1–4; shadow pilot on terms agreed after the study).

Questions & regulatory scope

Common questions · Water Sentinel (Sewer saline intrusion tracing & H2S scrubber dosing)

Designed to work with: Read-Only Conductivity & H2S Logs · Sewer Network Maps & Dewatering Permits · 20 Moving Loggers (Pilot Phase)

How did Bayesian logger placement compare with an experienced engineer in simulation?

Moving 20 portable conductivity loggers narrowed simulated salt inflows in ~7 nights on average vs 11–15 nights for an expert bisecting branches (within 14 nights the expert also pinned ≥2 of 3 inflows in 51 of 64 campaigns vs 59 of 64 within 5 nights for the model), though with 8 loggers the model made ~4.6 more wasted inspections and a deeper water table removes statistical clarity over the expert.

How did H2S scrubber chemical dosing perform against a tuned operator rule?

Against a time-banded pH schedule, simulated caustic use fell 12–13% (98% vs 94–97% hours in limit), whereas a tuned operator rule on the same accurate H2S sensor used 1–2% less caustic than Nodal with more hours over the limit (and at 2× sulphide load Nodal's saving dropped to 4.5% with 10% hours over limit).

What happens in the first 4 weeks?

A read-only catchment diagnostic at AED 0 upfront using existing station logs, network maps and dewatering permits, with zero field hardware or SCADA login.